| Part No. | CPC-CAT6A-SFTP-GN-3FT |
| Product ID | 090103001 |
| MOQ | 1 Piece |
| Lead Time | 7-10 Working Days according to Quantity |
Product Highlights
Exceed ANSI/TIA-568.2-D Category 6A and ISO 11801 Class EA Standards
Up to 550MHz with 10G-T Speed, Support PoE/PoE+/PoE++ (IEEE 802.3af/at/bt)
S/FTP Cable Minimizes EMI and RFI Interference
Performance Tested with Fluke and Wired T568B
Use in Patch Panel or Equipment Connections in Enterprise Networks and Data Center
See More
Description
Cat6a network patch cable is the cost-effective solution for indoor data center applications, supporting up to 10GBase-T and 550MHz within 100 meters of cable. And it is fully backward compatible with all the previous categories. The FS cat6a patch cables conductor apply Pure Bare Copper with high electrical conductivity and low signal transmission attenuation. The shielded patch cord provides superior alien crosstalk (AXT) suppression and protects critical data from electromagnetic and radio frequency interference (EMI/RFI). The sheath material is new environmentally friendly material PVC CM, which is durable, flame-retardant, resistant to bending. Stranded copper patch cable can be used with a longer flex-life. The cable supports PoE to save you the expense and effort of powering PoE devices individually. You can also install PoE devices in locations distant from power outlets, such as high on walls, ceilings or poles. Cat6a cable uses eight-core four-pair precision twisted pairing technology and passes the Fluke test, which ensures that it can provide stable high-speed network connection and ensure the accuracy and reliability of data transmission.
Specifications
| Cable Type | Cat6a Snagless | Shielding Type | Shielded (S/FTP) |
| Cable Jacket | PVC CM (Round) | Length | 3ft (0.9m) (Including Plugs) |
| Conductor Material | Pure Bare Copper | Conductor Type | Stranded |
| Data Rate Support | 10GBase-T | Maximum (Tested) Frequency | 550MHz |
| Gauge (AWG) | 26 (7/0.16mm) | Cable Outer Diameter (mm) | 6.2 ± 0.3 |
| Max Transmission Distance | 100m | Twisted Pairs | 4 Pairs |
| Wire Scheme | T568B, Straight | Standard | ISO/IEC 11801, ANSI/TIA-568.2-D |
| Operating Temperature | -20 to +75°C (-4 to 167°F) | Installation Temperature | -10 to +50°C (14 to 122°F) |
Features
Double Shielded Patch Cable Ensures Data Security
550MHz Stable Transmission
50μ〞Gold-plated Connectors
Pure Copper Conductors
4 Twisted Pairs
Triple Protection of Patch Cables
RJ45 Modular Plug
PVC Jacket
Strain Relief Boot
PoE Connectivity for Enterprise
Copper Cabling Solutions for Data Center
Fluke Networks-Cable Testing
One-stop Solution to Network Cabling